CMTI-8010A

High Voltage 50 Ω Pulse Generator for CMTI Application

The CMTI-8010A is a high voltage 50 Ω pulse generator for static and dynamic common mode transfer interference (CMTI) evaluations of digital isolators according IEC-60747-5-5 and IEC-60747-17.

Features

  • High voltage 50 Ω pulse generator for static and dynamic common mode transfer interference (CMTI) evaluations of digital isolators according IEC-60747-5-5 and IEC-60747-17
  • 10000 V/ns CMTI slew rate at 3 kV open load output voltage and 0.3 ns rise time
  • 80 kW output power into 50 Ω load
  • 8 programmable pulse rise times out of: 20 ns, 10 ns, 7 ns, 5 ns, 3.5 ns, 2 ns, 1 ns, 0.6 ns, 0.3 ns. Other values on request.
  • 100 ns pulse width
  • Optional external pulse width extensions from 5 ns to 500 ns (up to 2 µs on request) using the external pulse width extender TLP-8012A5
  • High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)
  • Built-in pulse reflection suppression
  • 200 ms pulse repetition rate
  • Application programming interface (API): software macros to control pulse generator in standalone operation
  • Integrated interlock safety shut-down needed for pulse widths beyond 500 ns
  • Industrial isolated and EMI/ESD protected USB control interface
  • Two years warranty on the total system

Download: Product Datasheet CMTI-8010A

CMTI-8010A Schematic Front View

CMTI-8010A Schematic Rear View

Accessories suitcase included with CMTI-8010A (typical set)

Item Sub-Item Qty. Descriptions Model Number
1 1.0 1 High voltage 50 Ω pulse generator for static and dynamic common mode transfer interference evaluations of digital isolators according IEC-60747-5-5 and IEC-60747-17. An interlock safety switch is implemented inside the CMTI-8010A in order to guarantee safe usage of the high voltage capabilities. The customer has to provide adequate measurement set-up housing to guarantee the safety of the operators. CMTI-8010A
1.3 4 BNC(m) to SMA(fm) adaptor BNC(m)/SMA(fm)
1.4 2 SMA(m)/SMA(m) adaptor SMA(m)/SMA(m)
1.5 2 SMA(f)/SMA(f) adaptor SMA(f)/SMA(f)
1.6 2 50 Ω high performance SMA cable 2m, Sucoflex 104 SF104-2m
1.7 4 HV-BNC cables to combine pulse widths up to 1.5 µs HV-BNC C4A Kit
1.8 1 High voltage attenuator 50 Ω, 34 dB, 3 GHz, 2 kV HVA-34A
1.9 1 Transient voltage suppressor protection for scope input TVS-70MF-10
1.10 1 Power line cable according supply voltage, 1.5 m PLC-150A
1.11 1 SMA torque wrench 74Z-0-0-21
1.12 1 Hardware manual CMTI-8010A CMTI-HM
1.13 1 Safety switch to allow 2 µs pulse width CMTI-IN-LO
1.14 1 USB 2.0 Cable A Male to B Male 9.84″ (3.00m) Shielded 102-1030-BL-F0300