{"id":358,"date":"2013-06-30T08:34:47","date_gmt":"2013-06-30T08:34:47","guid":{"rendered":"http:\/\/www.hppi.de\/?page_id=358"},"modified":"2026-02-02T07:56:09","modified_gmt":"2026-02-02T07:56:09","slug":"pulse-generators","status":"publish","type":"page","link":"https:\/\/www.hppi.de\/?page_id=358","title":{"rendered":"Pulse Generators"},"content":{"rendered":"<h1>50 \u03a9 High Voltage Pulse Generators<\/h1>\n<ul>\n<li>The TLP-3010C pulse generator (with optional pulse width extender TLP-3011C) is the widely used, full feature set, 30 A working horse for the semiconductor industry<\/li>\n<li>The CMTI-3010C is a high voltage 50 \u2126 pulse generator optimized for static and dynamic common mode transfer interference (CMTI) evaluations of digital isolators according IEC-60747-5-5 and IEC-60747-17 at a CMTI slew rate up to 15 000 V\/ns<\/li>\n<li>The TLP-4010C (with optional pulse width extender TLP-3011C) gives 30 % increased output current<\/li>\n<li>The CMTI-4010C is a high voltage 50 \u2126 pulse generator optimized for static and dynamic common mode transfer interference (CMTI) evaluations of digital isolators according IEC-60747-5-5 and IEC-60747-17 at a CMTI slew rate up to 20 000 V\/ns<\/li>\n<li>The TLP-8010A (with optional pulse width extender TLP-8012A5) has 80 A extremely high output current including manual pulse width setting up to 500 ns at economical cost<\/li>\n<li>The CMTI-8010A is a high voltage 50 \u2126 pulse generator optimized for static and dynamic common mode transfer interference (CMTI) evaluations of digital isolators according IEC-60747-5-5 and IEC-60747-17 at a CMTI slew rate up to 10 000 V\/ns<\/li>\n<li>The CMTI-8010C offers enhanced features and ultra-fast CMTI slew rates up to 20 000 V\/ns <\/li>\n<li>The TLP-8010C (with optional TLP-8012A5 and\/or TLP-3011C extenders) is the well proven and widely used 80 A TLP\/VF-TLP\/HMM test system, which combines the TLP-8010A and TLP-4010C feature set into one system<\/li>\n<li>The TLP-12010C (with optional TLP-12012A6 and\/or TLP-3011C extenders) is the most advanced 120 A TLP\/VF-TLP\/HMM test system, which combines the TLP-12010A and TLP-4010C feature set into one system<\/li>\n<li>The TLP-16010A (with optional pulse width extender TLP-16012A) delivers 4 kV into 50 \u2126 and 160 A short circuit output current, including manual pulse width setting, for extreme device testing conditions<\/li>\n<li>The TLP-16010C (with optional pulse width extender TLP-16012A and TLP-3011C) delivers 4 kV into 50 \u2126 and 160 A short circuit output current for extreme device testing conditions. The TLP-16010C combines the performance of TLP-16010A and TLP-4010C in one machine to enable the full feature set.<\/li>\n<\/ul>\n<h1>50 \u03a9 High Voltage Pulse Generators<\/h1>\n<table>\n<tbody>\n<tr>\n<td><strong>Type<\/strong><\/td>\n<td><strong>TLP<\/strong><\/td>\n<td><strong>VF-TLP<\/strong><\/td>\n<td><strong>Rise Times<sup>1)<\/sup><\/strong><\/td>\n<td><strong>HMM<\/strong><\/td>\n<td><strong>Voltage (50 \u03a9) <\/strong><\/td>\n<td><strong>Current (Short)<\/strong><\/td>\n<td><strong>HMM-Level<\/strong><\/td>\n<td><strong>Datasheet<\/strong><\/td>\n<\/tr>\n<tr>\n<td><a title=\"TLP-3010C\" href=\"https:\/\/www.hppi.de\/?page_id=97\">TLP-3010C<\/a><\/td>\n<td>\u2713<\/td>\n<td>\u2713<\/td>\n<td>6<\/td>\n<td>\u2713<\/td>\n<td>750 V<\/td>\n<td>30 A<\/td>\n<td>8 kV<\/td>\n<td><a href=\"https:\/\/www.hppi.de\/files\/TLP3010C.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">PDF<\/a><\/td>\n<\/tr>\n<tr>\n<td><a title=\"CMTI-3010C\" href=\"https:\/\/www.hppi.de\/?page_id=2276\">CMTI-3010C<\/a><\/td>\n<td>\u2713<\/td>\n<td>&#8212;<\/td>\n<td>8<\/td>\n<td>&#8212;<\/td>\n<td>750 V<\/td>\n<td>30 A<\/td>\n<td>&#8212;<\/td>\n<td><a href=\"https:\/\/www.hppi.de\/files\/CMTI3010C.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">PDF<\/a><\/td>\n<\/tr>\n<tr>\n<td><a title=\"TLP-4010C\" href=\"https:\/\/www.hppi.de\/?page_id=301\">TLP-4010C<\/a><\/td>\n<td>\u2713<\/td>\n<td>\u2713<\/td>\n<td>6<\/td>\n<td>\u2713<\/td>\n<td>1 kV<\/td>\n<td>40 A<\/td>\n<td>10 kV<\/td>\n<td><a href=\"https:\/\/www.hppi.de\/files\/TLP4010C.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">PDF<\/a><\/td>\n<\/tr>\n<tr>\n<td><a title=\"CMTI-4010C\" href=\"https:\/\/www.hppi.de\/?page_id=2257\">CMTI-4010C<\/a><\/td>\n<td>\u2713<\/td>\n<td>&#8212;<\/td>\n<td>8<\/td>\n<td>&#8212;<\/td>\n<td>1 kV<\/td>\n<td>40 A<\/td>\n<td>&#8212;<\/td>\n<td><a href=\"https:\/\/www.hppi.de\/files\/CMTI4010C.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">PDF<\/a><\/td>\n<\/tr>\n<tr>\n<td><a title=\"TLP-8010A\" href=\"https:\/\/www.hppi.de\/?page_id=305\">TLP-8010A<\/a><\/td>\n<td>\u2713<\/td>\n<td>&#8212;<\/td>\n<td>6<\/td>\n<td>\u2713<\/td>\n<td>2 kV<\/td>\n<td>80 A<\/td>\n<td>15 kV<\/td>\n<td><a href=\"https:\/\/www.hppi.de\/files\/TLP8010A.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">PDF<\/a><\/td>\n<\/tr>\n<tr>\n<td><a title=\"CMTI-8010A\" href=\"https:\/\/www.hppi.de\/?page_id=2109\">CMTI-8010A<\/a><\/td>\n<td>\u2713<\/td>\n<td>&#8212;<\/td>\n<td>8<\/td>\n<td>&#8212;<\/td>\n<td>2 kV<\/td>\n<td>80 A<\/td>\n<td>&#8212;<\/td>\n<td><a href=\"https:\/\/www.hppi.de\/files\/CMTI8010A.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">PDF<\/a><\/td>\n<\/tr>\n<tr>\n<td><a title=\"CMTI-8010C\" href=\"https:\/\/www.hppi.de\/?page_id=2153\">CMTI-8010C<\/a><\/td>\n<td>\u2713<\/td>\n<td>&#8212;<\/td>\n<td>8<\/td>\n<td>&#8212;<\/td>\n<td>2 kV<\/td>\n<td>80 A<\/td>\n<td>&#8212;<\/td>\n<td><a href=\"https:\/\/www.hppi.de\/files\/CMTI8010C.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">PDF<\/a><\/td>\n<\/tr>\n<tr>\n<td><a title=\"TLP-8010C\" href=\"https:\/\/www.hppi.de\/?page_id=309\">TLP-8010C<\/a><\/td>\n<td>\u2713<\/td>\n<td>\u2713<sup>2)<\/sup><\/td>\n<td>6<\/td>\n<td>\u2713<\/td>\n<td>2 kV<\/td>\n<td>80 A<\/td>\n<td>15 kV<\/td>\n<td><a href=\"https:\/\/www.hppi.de\/files\/TLP8010C.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">PDF<\/a><\/td>\n<\/tr>\n<tr>\n<td><a title=\"TLP-12010A\" href=\"https:\/\/www.hppi.de\/?page_id=2052\">TLP-12010A<\/a><\/td>\n<td>\u2713<\/td>\n<td>&#8212;<\/td>\n<td>6<\/td>\n<td>\u2713<\/td>\n<td>3 kV<\/td>\n<td>120 A<\/td>\n<td>32 kV<\/td>\n<td><a href=\"https:\/\/www.hppi.de\/files\/TLP12010A.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">PDF<\/a><\/td>\n<\/tr>\n<tr>\n<td><a title=\"TLP-12010C\" href=\"https:\/\/www.hppi.de\/?page_id=1970\">TLP-12010C<\/a><\/td>\n<td>\u2713<\/td>\n<td>\u2713<sup>2)<\/sup><\/td>\n<td>6<\/td>\n<td>\u2713<\/td>\n<td>3 kV<\/td>\n<td>120 A<\/td>\n<td>32 kV<\/td>\n<td><a href=\"https:\/\/www.hppi.de\/files\/TLP12010C.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">PDF<\/a><\/td>\n<\/tr>\n<tr>\n<td><a title=\"TLP-16010A\" href=\"https:\/\/www.hppi.de\/?page_id=2495\">TLP-16010A<\/a><\/td>\n<td>\u2713<\/td>\n<td>&#8212;<\/td>\n<td>1<\/td>\n<td>\u2713<\/td>\n<td>4 kV<\/td>\n<td>160 A<\/td>\n<td>43 kV<\/td>\n<td><a href=\"https:\/\/www.hppi.de\/files\/TLP16010A.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">PDF<\/a><\/td>\n<\/tr>\n<tr>\n<td><a title=\"TLP-16010C\" href=\"https:\/\/www.hppi.de\/?page_id=2590\">TLP-16010C<\/a><\/td>\n<td>\u2713<\/td>\n<td>\u2713<sup>2)<\/sup><\/td>\n<td>6<\/td>\n<td>\u2713<\/td>\n<td>4 kV<\/td>\n<td>160 A<\/td>\n<td>43 kV<\/td>\n<td><a href=\"https:\/\/www.hppi.de\/files\/TLP16010C.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">PDF<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><sup>1)<\/sup> number of software programmable built-in pulse rise times<br \/>\n<sup>2)<\/sup> up to 40 A<\/p>\n<h1>\u00b130 V to \u00b110 kV Solid-State 2-Pin HBM Pulse Generators<\/h1>\n<p>The HBM-SST-10A is a \u00b130 V to \u00b110 kV 2-pin HBM pulse generator according ANSI\/ESDA\/JEDEC JS-001 standard with C=100 pF, R=1.5 k\u03a9 discharge network, based on solid state GaN and Si-MOS discharge switch technology in order to overcome all known disadvantages of classical relay-based HBM pulse units. Optional: \u00b16 kV HBM-SST-6A.<\/p>\n<table>\n<colgroup>\n<col width=\"20%\" \/>\n<col width=\"60%\" \/>\n<col width=\"20%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td><strong>Type<\/strong><\/td>\n<td><strong>Description<\/strong><\/td>\n<td><strong>Datasheet<\/strong><\/td>\n<\/tr>\n<tr>\n<td><a title=\"HBM-SST-6A\" href=\"https:\/\/www.hppi.de\/?page_id=2797\">HBM-SST-6A<\/a><\/td>\n<td>\u00b130 V to \u00b16 kV Solid-State 2-Pin HBM Pulse Generator<\/td>\n<td><a href=\"https:\/\/www.hppi.de\/files\/HBM-SST-6A.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">PDF<\/a><\/td>\n<\/tr>\n<tr>\n<tr>\n<td><a title=\"HBM-SST-10A\" href=\"https:\/\/www.hppi.de\/?page_id=2644\">HBM-SST-10A<\/a><\/td>\n<td>\u00b130 V to \u00b110 kV Solid-State 2-Pin HBM Pulse Generator<\/td>\n<td><a href=\"https:\/\/www.hppi.de\/files\/HBM-SST-10A.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">PDF<\/a><\/td>\n<\/tr>\n<tr>\n<td><a title=\"HBM-TS10-A\" href=\"https:\/\/www.hppi.de\/?page_id=1323\">HBM-TS10-A<\/a><\/td>\n<td>\u00b130 V to \u00b110 kV ANSI\/ESDA\/JEDEC Stand-Alone HBM Test System<\/td>\n<td><a href=\"https:\/\/www.hppi.de\/files\/HBM-TS10-A.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">PDF<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>50 \u03a9 High Voltage Pulse Generators The TLP-3010C pulse generator (with optional pulse width extender TLP-3011C) is the widely used, full feature set, 30 A working horse for the semiconductor <a class=\"more-link\" href=\"https:\/\/www.hppi.de\/?page_id=358\">Continue Reading \u2192<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-358","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hppi.de\/index.php?rest_route=\/wp\/v2\/pages\/358","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hppi.de\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hppi.de\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hppi.de\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hppi.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=358"}],"version-history":[{"count":56,"href":"https:\/\/www.hppi.de\/index.php?rest_route=\/wp\/v2\/pages\/358\/revisions"}],"predecessor-version":[{"id":2883,"href":"https:\/\/www.hppi.de\/index.php?rest_route=\/wp\/v2\/pages\/358\/revisions\/2883"}],"wp:attachment":[{"href":"https:\/\/www.hppi.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=358"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}