{"id":1323,"date":"2016-01-13T20:31:32","date_gmt":"2016-01-13T20:31:32","guid":{"rendered":"http:\/\/www.hppi.de\/?page_id=1323"},"modified":"2025-10-27T15:19:00","modified_gmt":"2025-10-27T15:19:00","slug":"hbm-ts10-a","status":"publish","type":"page","link":"https:\/\/www.hppi.de\/?page_id=1323","title":{"rendered":"HBM-TS10-A"},"content":{"rendered":"<h1>\u00b110 kV ANSI\/ESDA\/JEDEC HBM Test System<\/h1>\n<h2>Features<\/h2>\n<ul>\n<li>\u00b110 kV Human-Body-Model (HBM) tester according ANSI\/ESDA\/JEDEC JS-001 standard with C = 100 pF, R = 1.5 k\u03a9 discharge network<\/li>\n<li>Wafer, package and system level HBM testing<\/li>\n<li><span style=\"color:#ED1847\">True HBM:<\/span> the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions<\/li>\n<li>No trailing pulses<\/li>\n<li>Integrated 10 k\u2126 charge removal resistor<\/li>\n<li>Integrated DUT HBM current sensor for real time transient current monitoring with 1V\/A output sensitivity into 50 \u2126 digital oscilloscope input<\/li>\n<li>Integrated DUT HBM voltage sensor for real time transient voltage monitoring with 1\/200V\/V output sensitivity into 50 \u2126 digital oscilloscope input<\/li>\n<li>Integrated overvoltage protection of the DUT voltage sensor, DUTcurrentsensor and DC test interface for efficient overload protection of the digital oscilloscope and SMU during high voltage HBM testing<\/li>\n<li>Integrated DC test DUT switch with automatic switch control<\/li>\n<li>Integrated 50 \u2126 precision hardware trigger output for high speed digital oscilloscopes<\/li>\n<li>Fast HBM measurements, typically 0.5s per pulse including one-point DC measurement between pulses<\/li>\n<li>Eficient sofware for system control and waveform data management (fully compatible with TLP measurement data)<\/li>\n<li>The sofware can control automatic probers for fast measurements of complete wafers<\/li>\n<li>System controller size 483 mm x 487 mm x 133 mm<\/li>\n<li><span style=\"color:#ED1847\">Optionally available hardware upgrades<\/span> to all HPPI fully integrated HBM\/HMM\/TLP\/VF-TLP test systems TLP-xxx10y<\/li>\n<\/ul>\n<h2>Downloads<\/h2>\n<p><strong>Download:<\/strong> <a href=\"https:\/\/www.hppi.de\/files\/HBM-TS10-A.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Product Datasheet HBM-TS10-A<\/a> <\/p>\n<h2>Block Diagram<\/h2>\n<p><a href=\"https:\/\/www.hppi.de\/wp-content\/uploads\/2025\/10\/HBM_Test_System_BD_SST-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.hppi.de\/wp-content\/uploads\/2025\/10\/HBM_Test_System_BD_SST-scaled.jpg\" alt=\"\" width=\"2560\" height=\"1466\" class=\"aligncenter size-full wp-image-2751\" srcset=\"https:\/\/www.hppi.de\/wp-content\/uploads\/2025\/10\/HBM_Test_System_BD_SST-scaled.jpg 2560w, https:\/\/www.hppi.de\/wp-content\/uploads\/2025\/10\/HBM_Test_System_BD_SST-300x172.jpg 300w, https:\/\/www.hppi.de\/wp-content\/uploads\/2025\/10\/HBM_Test_System_BD_SST-1024x586.jpg 1024w, https:\/\/www.hppi.de\/wp-content\/uploads\/2025\/10\/HBM_Test_System_BD_SST-768x440.jpg 768w, https:\/\/www.hppi.de\/wp-content\/uploads\/2025\/10\/HBM_Test_System_BD_SST-1536x880.jpg 1536w, https:\/\/www.hppi.de\/wp-content\/uploads\/2025\/10\/HBM_Test_System_BD_SST-2048x1173.jpg 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/a><\/p>\n<h2>Photograph HV-CU10-A and HBM-SST-10A<\/h2>\n<p><a href=\"https:\/\/www.hppi.de\/wp-content\/uploads\/2025\/10\/hv-cu10-a_plus_hbm-tss-10a.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.hppi.de\/wp-content\/uploads\/2025\/10\/hv-cu10-a_plus_hbm-tss-10a.jpg\" alt=\"\" width=\"1366\" height=\"613\" class=\"aligncenter size-full wp-image-2749\" srcset=\"https:\/\/www.hppi.de\/wp-content\/uploads\/2025\/10\/hv-cu10-a_plus_hbm-tss-10a.jpg 1366w, https:\/\/www.hppi.de\/wp-content\/uploads\/2025\/10\/hv-cu10-a_plus_hbm-tss-10a-300x135.jpg 300w, https:\/\/www.hppi.de\/wp-content\/uploads\/2025\/10\/hv-cu10-a_plus_hbm-tss-10a-1024x460.jpg 1024w, https:\/\/www.hppi.de\/wp-content\/uploads\/2025\/10\/hv-cu10-a_plus_hbm-tss-10a-768x345.jpg 768w\" sizes=\"auto, (max-width: 1366px) 100vw, 1366px\" \/><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u00b110 kV ANSI\/ESDA\/JEDEC HBM Test System Features \u00b110 kV Human-Body-Model (HBM) tester according ANSI\/ESDA\/JEDEC JS-001 standard with C = 100 pF, R = 1.5 k\u03a9 discharge network Wafer, package and <a class=\"more-link\" href=\"https:\/\/www.hppi.de\/?page_id=1323\">Continue Reading \u2192<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1323","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hppi.de\/index.php?rest_route=\/wp\/v2\/pages\/1323","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hppi.de\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hppi.de\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hppi.de\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hppi.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1323"}],"version-history":[{"count":18,"href":"https:\/\/www.hppi.de\/index.php?rest_route=\/wp\/v2\/pages\/1323\/revisions"}],"predecessor-version":[{"id":2795,"href":"https:\/\/www.hppi.de\/index.php?rest_route=\/wp\/v2\/pages\/1323\/revisions\/2795"}],"wp:attachment":[{"href":"https:\/\/www.hppi.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1323"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}